Step 8 - Identify those BOF tubes that are to have fibers installed and install fibers into them in accordance with the manufacturer's instructions.
Step 9 - For each BOF tube containing fibers, install a tube furcation unit onto the tube in accordance with Method 2F1 of this standard and terminate the furcation cables in accordance with part 5 of this standard.
Step 10 -Form and shape the optical fiber cables and furcation unit's loose tube furcation cables within the interconnection box in accordance with Method 2C1 of this standard.
Step 11 -For each BOF tube containing fibers, verify the integrity of the end seals in accordance with Method 6J1 of this standard.
Heat shrink label
Fiber Optic Interconnection Box
Tube
Patch panel
7-Tube clip or equal
DO NOT EXCEED Bend Diameter [13 cm (5 in.)]
7-Tube Cable
FIGURE 2I2-1. Routing BOF tubes in a FOICB.
2I2-3 METHOD 2I2