FIGURE 2Dl-2. Inserting ferrule into alignment sleeve.
Step 4 - Dip the other ferrule tip into the index matching gel and slide the ferrule tip into the other side of the alignment clip (see figure 2Dl-
3). Ensure that the ferrule tips are centered in the alignment clip and the alignment tabs are facing the clip gap. Remove the alignment clip tool from the alignment clip. Verify that the ferrule tips are in contact by pushing the ferrules together.
Alignment clip
Ferrule
Alignment clip tool
FIGURE 2Dl-3. Inserting second ferrule into alignment sleeve.
3.2.2 Splice alignment.
NOTE: Passive alignment should be sufficient for most applications. Active alignment shall only be performed when required to meet link acceptance requirements.
2Dl-3 METHOD 2Dl