90 Degree angle tube
ASTM F1836M/2
Body
Cap
Packing assembly
"O"-Ring
Locknut
Enclosure wall thickness 19 mm max.
Clearance hole
FIGURE 2G1-3. 90o angle tube.
Step 6 - Screw the locknut onto the body and tighten with a wrench against the "O"-ring sufficiently to obtain plastic to metal contact of the stuffing tube and the enclosure. In cases where this plastic to metal contact cannot be obtained, tighten the locknut until the threads
start to skip. This is considered a satisfactory indication of tightness. (Note: Hold the stuffing tube body while tightening the locknut to prevent turning.) Proceed to step 8 below.
Step 7 - With NPT tubes, screw the tube into the enclosure pipe thread and tighten it sufficiently to obtain a seal at the threads (see figure
2G1-4).
NPT Tube
ASTM F1836M/3
Body
Cap
Cast enclosure wall thickness over
2mm to 19 mm
Packing assembly
NPT
FIGURE 2G1-4. NPT tube.
Step 8 - Measure the distance required to route the BOF tubes from innermost portion of the stuffing tube to the most distant corner of the interconnection box (or to the furcation or end sealing region in the end user equipment). Add approximately 130 mm (5 in) to the distance and mark the BOF cable outer jacket.
Step 9 - Slide the stuffing tube parts onto the BOF cable in the order indicated:
a. Cap
b. Two slip washers
2G1-4 METHOD 2G1