MIL-STD-2042-6B(SH)
Reference cable
Test jumper
ST's, termini,
or splice ferrules
Light
source
ST
connectors
Power meter
FIGURE 6F1-4. Connecting the test jumper. Step 10 -Record the power at the meter (P2).
Step 11 -Calculate the ST, terminus or splice connection loss using the
following formula:
BC = ( Pl - P2 )
Where: BC = ST, terminus or splice connection loss in dB P1 = Reference cable power in dBm
P2 = Test power in dBm
Step 12 -Record the ST, terminus or splice connection loss along with the test jumper identification.
Step 13 -Repeat step 9 through step 12 a minimum of three times (a maximum of ten times) for the selected MQJ. (A wipe dampened with alcohol may be used to clean the adapters/connectors and they may be blown dry with air before making each connection.)
3.3 Calculations.
Step 1 - Calculate the mean loss for each end of the MQJ using the following formula and record the results:
l m
μC = x ∑Bn
n=l
Where: uC = Mean connection loss in dB
Bn = Connection loss for measurement n in dB
m = Number of loss measurements performed
Step 2 - Calculate the standard deviation of the measured loss for each MQJ end using the following formula and record the results:
m
∑(Bn
- μC )
α C =
n=l
m −1
Where: sc = Standard deviation of the connection loss in dB
m = Number of loss measurements performed
6F1-5
METHOD 6F1