MIL-STD-2042-6B(SH)
1. SCOPE.
METHOD 6F1
MEASUREMENT QUALITY JUMPER CABLE SELECTION TEST
1.1 Scope. This method describes procedures for measuring the loss of measurement quality jumper cable end terminations. Alternative methods shall be approved by the Naval Surface Warfare Center (see 1.1.1).
2. REQUIRED EQUIPMENT AND MATERIALS.
2.1 The equipment and materials in the tables located in the applicable sections of this method shall be used to perform these procedures.
3. PROCEDURES.
3.1 Safety summary. The following safety precautions shall be observed:
a. Safety glasses shall be worn when handling bare fibers.
b. Do not touch the end of the fibers as they may be razor sharp. Wash your hands after handling bare fiber.
c. Observe warnings and cautions on equipment and materials.
d. When visually inspecting an optical fiber, never stare into the end of a fiber connected to a laser source or LED.
3.2 Procedure.
3.2.1 The equipment and materials in table 6F1-I shall be used to perform this procedure.
TABLE 6F1-I. Equipment and materials.
Description |
Quantity |
Wipes (NAVSEA DWG 6872811-18 or equal) |
As required |
Alcohol bottle with alcohol/2-propanol (sealable type) |
1 |
Canned air or compressed air |
As required |
Reference cable (ST on both ends) |
1 |
Reference cable (ST to MIL-T-29504/14 pin terminus) |
1 |
Reference cable (ST to MIL-T-29504/15 socket terminus) |
1 |
Reference cable (ST to MIL-S-24623/4 splice ferrule) |
1 |
Light source (NSN 7Z 6625 01 304 1739 or equal) |
1 |
Power meter (NSN 7Z 6625 01 304 1739 or equal) |
1 |
6F1-1
METHOD 6F1
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business