MIL-STD-2042-6B(SH)
c. Color code - BOF fiber colorations should be easily discernable.
3.3 Procedure II. Connector, splice and interconnection box inspection.
Step l - Examine the documentation to ensure that the components conform to the requirements of the applicable Military Specifications.
Step 2 - Examine the components for the following:
a. Damage - missing or loose parts, dents, cracks, chips, burrs, or peeling or chipping of the plating or finish.
b. Marking - As a minimum, the part number and manufacturer's identification (Acceptance Test only).
6Al-2 METHOD 6Al