MIL-STD-2042-lB(SH)
Meltable
Overall
Jacket
25 mm min
Expanded end cap
FIGURE lAl-l. Installing expanded end cap on cable.
Step 5 - CAUTION: Do not overheat the cable. Prolonged exposure of the jacket to temperatures above l60oC (320oF) may damage the cable
jacket. Discontinue heating of the sleeve and allow the cable jacket to cool before reheating, if the cable jacket shows any signs of bubbling.
Hold the heat gun approximately l00 mm (4 in) from the end cap and as heat is applied, move the heat gun back and forth over the end cap. Shrink the end cap from closed end to open end to avoid trapping air. (NOTE: Minimum recovery temperature is l2loC (250oF).
Step 6 - When the end cap has recovered enough to assume the configuration of the cable and excess adhesive appears at the end of the cap, discontinue heating (see figure lAl-2). (NOTE: Additional heat will not make end cap shrink more tightly.)
Overall Adhesive jacket
Recovered end cap
FIGURE lAl-2. Completed end seal.
lAl-3
METHOD lAl