MIL-HDBK-2051(SH)
5.4.1.3.1 Cable routing to multiple interconnection boxes in a service area. If more than one interconnection box is required in an interconnection box service area, the cables entering that area should be separated between
the boxes based on the point of compartment entry. For example, cables coming from aft sections should be terminated in one interconnection box while cables from forward sections should be terminated in the other box.
5.4.1.4 Local cable end user equipment interface . The termination on the local cable that interfaces to the end user equipment should be compatible
with the system equipment. Single fiber connectors can be used for this interface, however, the single fiber connectors should be mounted internally to the equipment or in an equipment rack. Single fiber connectors should not be mounted externally to the equipment. Multifiber connectors can also be used for this interface. Figures 9 and 10 show typical local cable end user equipment terminations.
Trunk fibers Splice tray Local fibers
NRG Redundant
NRG
Redundant
Spare
Spare
(a) NRG and redundant fibers
Trunk fibers Splice tray Local fibers
Alternate Alternate Alternate Normal
Normal
Spare
(b) Normal and alternate fibers
Figure 8. Splice tray configuration.
22