MIL-HDBK-2051(SH)
5.4.1.3 Interconnection box configuration . The interconnection box should be configured to provide ready access to redundant and growth fibers. The connector module should be filled starting with the row closest to the inside
of box and working outward (see figure 6). Normal and alternate fibers should be mounted nearest the inside of the box. NRC fibers should be mounted next. NRC fibers terminated with connectors should be mounted on a separate row with the corresponding redundant fibers mounted in the row immediately above the
NRC fibers. Unused adaptors should be mounted closest to the outside of the interconnection box. For splices, the normal, alternate, NRC and redundant fibers should be separated from growth and unused splice locations (see figure
7). NRC fibers terminated with splices should be mounted in separate trays from normal and alternate channels, with the redundant fiber located immediately next to the corresponding NRC fiber (see figure 8).
Unused
Patch panel
Allocated
Spares
Inside of box
FIGURE 6. Patch panel configuration.
Unused
FIGURE 7. Splice tray holder configuration.
21