MIL-STD-690D
w/ CHANGE 1
5. DETAILED REQUIREMENTS
5.1 Procedure I, "Qualification at the initial FR level". Qualification at the initial FR level shall be predicated upon accumulation of valid data meeting the requirements of 5.1.2a or 5.1.2b, as applicable. FR tests shall be conducted for the specified duration and single sample size. The qualifying activity may grant qualification at a FR level lower than that specified provided the manufacturer performs all tests required for initial qualification and submits valid data from current production which substantiates lower failure rates.
5.1.1 Applicable data. Data shall be accumulated from sample units selected from a production run and produced with equipment and procedures normally used in production. One of the prerequisites for valid data is that all lots produced during the production period are represented. The data shall be from the same product in current production; i.e., data from products of preceding designs shall not be acceptable.
5.1.2 FR sampling plans (FRSP).
a. |
Single sampling plans based on a 60 percent confidence level are provided in table I (see table A-I of appendix A). |
|
b. |
Single sampling plans based on a 90 percent confidence level are provided in table II (see table A-I of appendix A). |
|
* |
TABLE I. FRSP-60. |
FR level symbol |
Qualified FR level 1/ |
Cumulative unit hours in millions (c = number of failures permitted) |
||||||||||
c=0 |
c=1 |
c=2 |
c=3 |
c=4 |
c=5 |
c=6 |
c=7 |
c=8 |
c=9 |
c=10 |
||
L M P R or U 3/ S or V 3/ |
%/1,000 hr 2/ 1.0 0.1 0.01 0.001 |
.0916 .916 9.16 91.6 |
.202 2.02 20.2 202 |
("M" .311 3.11 31.1 311 |
row .418 4.18 41.8 418 |
divided .524 5.24 52.4 524 |
by .629 6.29 62.9 629 |
"L") .735 7.35 73.5 735 |
.839 8.39 83.9 839 |
.943 9.43 94.3 943 |
1.048 10.48 104.8 1048 |
1.152 11.52 115.2 1152 |
1/ For FR level expressed in terms other than %/1,000 hour, see 4.1c and 4.1d.
2/ Where a FR level greater than 1.0 percent is required, level "L" shall be specified and the cumulative unit hours computed as shown.
3/ See 4.1a.
* TABLE II. FRSP-90.
FR level symbol |
Qualified FR level 1/ |
Cumulative unit hours in millions (c = number of failures permitted) |
||||||||||
c=0 |
c=1 |
c=2 |
c=3 |
c=4 |
c=5 |
c=6 |
c=7 |
c=8 |
c=9 |
c=10 |
||
L M P R or U 3/ S or V 3/ |
%/1,000 hr 2/ 1.0 0.1 0.01 0.001 |
.230 2.30 23.0 230 |
.389 3.89 38.9 389 |
("M" .532 5.32 53.2 532 |
row .668 6.68 66.8 668 |
divided .799 7.99 79.9 799 |
by .927 9.27 92.7 927 |
"L") 1.054 10.54 105.4 1054 |
1.171 11.71 117.1 1171 |
1.300 13.00 130.0 1300 |
1.421 14.21 142.1 1421 |
1.544 15.44 154.4 1544 |
1/ For FR level expressed in terms other than %/1,000 hour, see 4.1c and 4.1d.
2/ Where a FR level greater than 1.0 percent is required, level "L" shall be specified and the cumulative unit hours computed as shown.
3/ See 4.1a.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business