450
400
v = 350 for t < 0.05
350
300
250
290
240
200
150
100
50
0
0.01 0.1 1
7 10 100
Time from Onset of Overvoltage or Undervoltage, Seconds
FIGURE 17. Limits for DC overvoltage and undervoltage for 270 volts DC system.